Distance from sources exiting the roof.
10 away from property line exhaust in roof.
The termination of chimneys or vents equipped with power exhausters shall be located a minimum of 10 feet 3048 mm from the lot line or from adjacent buildings.
7 7 3 inlet is provided with rodent insect screen with 0 5 inch mesh.
Exhaust system shall operate whenever cooking equipment is turned on cmc 514 1 rooftop terminations per cmc 510 9 1 1.
The property line is only about 24 inches away from the side of their house and about 10 feet from the side of our home.
1 0 30 roof grade without snow accumulation.
10 3 private washrooms exhaust.
3 above any air intake within 10 2.
And directed away as much as possible from residential uses within 50 feet 15 240 mm of the vent in some locations.
10 from property lines 3.
I presume you re talking about an exhaust vent for some sort of fuel fired.
15 5 public washroom exhaust.
The exhaust shall be directed away from the building.
Ducts conveying explosive or flammable vapors fumes or dusts shall terminate not less than 30 feet 9144 mm from a property line 10 feet 3048 mm from openings into the building 6 feet 1829 mm from exterior walls or roofs 30 feet 9144 mm from combustible walls or openings into the building that are in the direction of the exhaust discharge and 10 feet 3048 mm above adjoining grade.
10 3 private road driveway 5 1 5 building exhaust clean 5 1 5 automobile parking area.
7 7 2 inlet is 2 ft.
Exhaust vents must not be allowed to be obscured or hidden by vegetation.
Exhaust vents must be protected against rain and equipped with back flow prevention features e g flap dampers.
Of stretched string distance from known contamination sources e g stack vent exhaust vehicles not exiting the roof and 3 ft.
1 0 30 property line.
In all areas exhaust vents should be at least 1 foot above roof surface.
Air exhaust openings shall terminate not less than 3 feet 914 mm from property lines.
Horizontal terminations shall comply with the following requirements.
The current chimney heat duct that they are using fills our home with smoke.
Thru the roof be installed from the property line july 2.
3 feet 914 mm from property lines.
Vegetation must not be allowed to grow within 3 feet of an exhaust vent.
Exhaust outlets extending to the roof shall extend 3 feet 914 mm above the roof surface.
Exhaust flow directed up and away from roof minimum 40 above roof electrical and roof access requirements 1.
3 feet 914 mm from operable openings into buildings for.